Plan your sign's lighting in seconds.

Enter a glow sign board or light box size to get the module count, spacing and power supplies — then send the plan to us on WhatsApp for a quote.

Leave blank to auto-set from depth and brightness, or enter your own spacing.

Modules—
Power supplies—
Total load—
Density—modules / sq ft

Estimates only. Spacing starts at box depth × brightness factor (1.8 / 1.5 / 1.2), limited to 60–250 mm, with modules spread evenly and half a space at each edge. SMPS capacity = 12V × rated current, loaded to 80%. Direct-220V modules need no SMPS. Always power a test layout before sealing the box.

Spacing follows depth

The deeper the box, the further light spreads before it hits the face — so modules can sit further apart. Shallow boxes need tighter spacing to avoid hot spots.

80% rule for power

We size power supplies at 80% of their rated output. A 31.6A StellarX (about 380W at 12V) carries about 300W, leaving headroom for heat, ageing and voltage dips.

Channel letters or odd shapes?

Letters, logos and cut-outs need a custom layout. Send the artwork and size on WhatsApp and we'll suggest the module count and power.

Get layout help

FAQ

Planning questions

How many modules can one power supply run?

Keep each supply at about 80% of its rating. A 31.6A supply such as StellarX, Comet or Lunar (about 380W at 12V) carries around 300W — roughly 200 Apollo modules (1.5W) or 165 Vega modules (1.8W). The sign calculator works it out for any board.

What module spacing should I use in a glow sign board?

A good starting point is about 1.5 times the depth of the box — roughly 150 mm in a 100 mm (4 in) deep box. Shallow boxes need tighter spacing to avoid hot spots. Always test on a panel before sealing.

Can I connect 12V LED modules directly to 220V mains?

No. 12V DC products (2W Samsung, Vega, Apollo, Titan Eco, Mini, Astra DC and Astra Waterproof) must always run through a 12V SMPS. Connecting them to 220V destroys them instantly and is a fire and shock risk. Only Ultra 220V, Nebula Square and Astra 220V are made for direct mains.

Can you help with my sign layout?

Yes. Send a photo or PDF of your artwork with the board size on WhatsApp and we'll suggest the module, spacing and power supply. For light boxes you can also use the online sign calculator.